The top tier for data centers is Tier 4 and Tier 4 Data Center Standards. Additionally, it is the most expensive. Tier 4 data centers comply with all Tiers 1, 2, and 3 requirements and make sure that all equipment is completely fault-resistant. It has numerous cooling systems, power sources, and backup generators, making it completely redundant.
When there is planned maintenance and unplanned outages. Downtime shouldn’t happen. Only 0.013% more downtime than a Tier 3 data center is projected annually, with an expected uptime of 99.995% (26.3 minutes). The majority of businesses will select Tier 3 data centers over Tier 4 Data Center Standards because of the modest availability improvement and lower cost compared to Tier 3 data centers.
You must take your IT requirements into account as well as availability when choosing a data center. Unless you have no other option and have a backup strategy in place to control how the business functions during an outage. Tier 1 and Tier 2 data centers are typically not suited for mission-critical workloads. Your important workloads should ideally only be housed in Tier 3 and Tier 4 Data Center Standards.
Arzhost provides VPS servers, dedicated servers, and web hosting in Tier 3+ data centers in the US. To learn more about our data center facilities, feel free to contact our sales department at sales@Arzhost.com or by phone at +631-594-8060.
Explain Tier 4 Data Center Standards
- The highest categorization for data center facilities at the moment is Tier IV. In actuality. Tier IV facilities are comparable to the government of United States data centers. They are extremely reliable, secure, and redundant.
- The four 9s are another name for Tier IV. Compared to 1.6 hours with a Tier III facility. Tier 4 Data Center Standards have a 99.995% availability rate and 0.8 hours of interruption every year. That is equal to 50% of a Tier III data center’s downtime.
- When Tier IV facilities do encounter downtime. It usually lasts only a brief period while failovers switch to backup systems.
- There are Tier IV recognized data centers that keep track of the number of minutes, seconds and even years since their last interruption.
- A Tier IV facility typically has 2N+1 Redundancy in terms of redundancy. The phrase “2N+1” refers to a facility that has two times the operational requirements plus a backup.
How Are Tier 4 Data Center Ratings Calculated?
Enterprise organizations frequently use Tier 4 Data Center Standards. Which offer the following services:
- A yearly uptime of 99.995% (Tier 4 Data Center Standards, uptime & Requirements)
- Fully redundant infrastructure with 2N+1 (the main difference between tier 3 and tier 4 data centers)
- 96-hour protection from power outages
- 3 minutes of downtime each year